***COMPLETE GUIDE SPECIFICATION***
SECTION 07 90 00 and 07 95 00 (formerly 05810 / 07102 / 07915)--
SEALANTS, CAULKING, & SEALS
Application: Watertight,
Energy-Efficient, 2-Hour Fire-Rated Expansion Joints--Basis of Design: EMSHIELD
WFR2
USA &
INTERNATIONAL: EMSEAL JOINT SYSTEMS, LTD, 25 Bridle Lane
Westborough, MA 01581-2603,
Toll
Free: 800-526-8365 or PH: 508-836-0280, FX: 508-836-0281,
www.emseal.com.
CANADA: EMSEAL, LLC, 120 Carrier Drive, Toronto, Ontario,
Canada, M9W 5RI Toll Free: 800-526-8365 or PH: 416-740-2090, FX:
416-740-0233,
www.emseal.com
PART 1 – GENERAL
1.01
RELATED DOCUMENTS
A.
The requirements of the GENERAL
CONDITIONS, SUPPLEMENTARY CONDITIONS and DIVISION 1 GENERAL
REQUIREMENTS apply to the work of this section.
1.02
DESCRIPTION
A. EMSHIELD WFR2 SYSTEM – Watertight,
energy-efficient, 2-Hour rated expansion joint by EMSEAL Joint Systems for
expansion joints and isolation joints in walls.
Typical locations include applications for exterior wall joints and
interior wall joints where a 2-hour fire rating is required or desired. System
shall perform waterproofing, fire-rating, movement-accommodation functions
as well as contribute to thermal insulation and sound attenuation as the result of a single
installation and without the addition of ancillary fire-blankets,
mineral wool, coverplates, etc.
1.03
RELATED WORK SPECIFIED ELSEWHERE
A.
CONCRETE
1.04
QUALITY ASSURANCE
A.
Manufacturer's Instructions: In
addition to requirements of these specifications, comply with
manufacturer's instructions and recommendations for all phases of
work, including preparation of substrate, applying materials, and
protection of installed units.
1.05
SUBMITTALS
General: Submit the following in accordance with
(Designer: Insert appropriate
section reference for submittals).
A. Product data in the form of manufacturer's product
specifications, installation instructions, and details for each type
of expansion joint sealant system indicated.
B. Samples
of same materials to be used in work including certification by
Underwriters Laboratories (UL) that product has been tested and
certified for UL 2079 and meets the requirements of ASTM E1966, ASTM
E119 and ASTM E1399.”
1.06
PRODUCT DELIVERY, STORAGE AND HANDLING
A. Deliver
materials as factory packaged, sealed, and labeled. Handle and
protect as necessary to prevent damage or deterioration during
shipment, handling and storage.
B. Follow
any special instructions by manufacturer or manufacturer’s
representative.
1.07
PROJECT CONDITIONS
A. Substrate
Condition:
Proceed with work only when substrate construction and preparation
work is complete and in condition to receive sealant system.
B. Weather
Conditions:
Perform work only when existing and forecasted weather conditions
are within the guidelines established by the manufacturer of the
sealant system.
PART 2 – PRODUCTS
2.01
ACCEPTABLE MANUFACTURERS
A. Manufacturers
known to be able to supply materials as specified:
EMSEAL JOINT SYSTEMS, LTD,
25 Bridle Lane Westborough, MA 01581-2603, Toll Free: 800-526-8365
or PH: 508-836-0280, FX: 508-836-0281,
www.emseal.com.
CANADA: EMSEAL, LLC, 120 Carrier
Drive, Toronto, Ontario, Canada, M9W 5RI Toll Free: 800-526-8365 or
PH: 416-740-2090, FX: 416-740-0233,
www.emseal.com
2.02 MATERIALS
A. EMSHIELD WFR2 SYSTEM – Sealant system shall be comprised of three
components:
1)
fire-retardant-impregnated foam pre-coated on both sides with an intumescent fire-proofing
material and pre-coated at the top layer with waterproof silicone; 2) field-applied epoxy adhesive primer, 3)
field-injected silicone sealant bands. Impregnation agent to have
proven non-migratory characteristics. Silicone coating to be
low-modulus, waterproof silicone applied to the
impregnated foam sealant at a width greater than maximum allowable
joint extension and which when cured and compressed will form a
bellows. Product must be proved to have been tested and UL/ULC
certified by Underwriters Laboratories to the joint-cycling and fire
testing standards of UL 2079.
B. EMSHIELD WFR2 foam
seal to be installed into manufacturer-supplied field-applied epoxy
adhesive. The EMSHIELD WFR2 SYSTEM is to be installed slightly
recessed from the surface wall such that when the field-applied injection
band of silicone is applied at the installation side between the substrates and the
foam-and-silicone-bellows, the system will be essentially flush with
the substrate surface. Material shall
be capable of movements of +25%, -25% (50% total) of nominal
material size. Standard sizes from 1” (25 mm) to 6” (150mm).
Depth of seal is 4” (100mm).
C. Substitute candidates in addition to
having been certified by UL according to UL2079, shall provide
certification in writing to be free in composition of any waxes or
asphalts, wax compounds or asphalt compounds. All substitute
candidates shall be certified in writing to be: a) capable of
withstanding 150°F (65°C) for 3 hours while compressed down to the
minimum of movement capability dimension of the basis of design
product (-25% of nominal material size) without evidence of any
bleeding of impregnation medium from the material; and b) that the
same material after the heat stability test will self-expand to the
maximum of movement capability dimension of the basis-of-design
product (+30% of nominal material size) within 24 hours at room
temperature 68°F (20°C).
D.
Factory-fabricated
universal-90-degree transition units shall be used
to transition all joints into horizontal plane surfaces (decks,
floors, etc).
Universal-90-degree transitions pieces to be single
units containing minimum 12-inch long leg and 6-inch long leg on
each side of the direction change unless modified at the factory for
custom installation sizes. Both outward-facing surfaces
of the entire unit to be continuously coated with both the intumescent
bellows and over that, waterproof silicone
bellows. Factory-fabricated units to be field-joined to straight lengths in
accordance with manufacturer’s prescribed methods and supplied
joining materials.
PART 3 – EXECUTION
3.01
INSPECTION
A.
Joint surfaces to receive seal shall be
sound, smooth, straight, parallel, clean, dry and free of all
visible contaminants. Applications of non-visible coatings or
contaminants to surfaces of joint interface area prior to
installation of seal shall be controlled by the Architect/Engineer
in consultation with the expansion joint manufacturer.
B. The
joint configuration and the joint surfaces shall be as detailed in
the drawings and in accordance with the contract specifications and
in compliance with requirements in the current material Tech Data
available from the Manufacturer. All known detrimental conditions
shall be reported immediately in writing. Field measurements of the
depth and width of the joint shall be supplied to manufacturer
before material is ordered.
3.02
INSTALLATION
A. Do not proceed with the installation of joint sealer
if the joint is other than designed, until written notification of
these conditions is submitted to the manufacturer and design
professional, and a written acknowledgement with an order to proceed
is provided.
B. Do not proceed with the installation of joint sealer
under adverse weather conditions when joint to be sealed is damp,
wet or frozen, or when temperatures are below or above the
manufacturer's recommended limitations for installation. Consult
manufacturer for specific instructions before proceeding.
C.
Joint sealer/expansion joint material to be installed in strict
accordance with the manufacturer's instructions and the advice of their official
representative.
3.03
CLEANING AND PROTECTION
A. Remove
all waste materials from site. Leave work in a condition
satisfactory to the Architect/Engineer.
END
OF SECTION |